  • BOWIE-DICK 134C/3.5 min TEST. Set: test device and strip tests. Package contains PCD device + 100 tests
Size
£88.47
incl. VAT / piece
of
Express checkout 1-Click(without registration)
The product is available in a very small amount
The product is available in a very small amount
14 days for easy returns
Safe shopping

BOWIE-DICK TEST 3.5 min/134°C

Kit containing device and strip tests

Autoclave performance checks are performed using the BOWIE & DICK test. Bowie-dick tests should be performed daily (before starting work), as well as after each repair/service, after moving the device to another location, and after any prolonged idleness.

Batch control - BOWIE-DICK test- indicator in class 2 technology. Tests are designed for 134°C / 3.5 min sterilization.

System for daily steam quality control in vacuum autoclaves. Designed to accurately check vapor penetration and behavior of all Bowie-Dick cycle parameters. The Bowie Dick test consists of a white polypropylene bulb for chemical strip tests, which is connected to a 1.5m Teflon tube. Bowie Dick test prematurely detects abnormalities during Bowie Dick test cycles, faults that are caught are:

  • sterilization at too low a temperature
  • sterilization keeps too short a time
  • insufficient vacuum value and number of vacuum pulses
  • insufficient removal of air from the depths of the equipment
  • insufficient steam penetration in hollow equipment
  • leakage from pipeline / valves / door seals
  • detection of the presence of a small volume of inert gases in the vapor supply
  • detection of excessive condensate

BOWIE-DICK test consists of the following:

  • 1 piece of Helix device (screw-on polypropylene tube with Teflon tubing with a length of. 1,5m)
  • self-adhesive chemical strip indicators (ISO 11140-1 class 2)
  • 1 pc. cotton bag
  • 1 pc. instruction with illustrated color change of indicator

Each strip of the blue chemical indicator is 6 mm wide and 38 mm long (entire test including description 7.6 cm). After a proper process, the indicator will turn from blue to pink.
BDHT is located in a cardboard box with dimensions of 178 x 125 x 50mm (D x S x W).
The label on the package includes: product description, contents of the carton, reference number, LOT number, production date, expiration date.

How to use and read the results
After 3.5 minutes at 134°C, the color changes from blue to pink. The behavior of the indicator depends on time, temperature, saturated steam properties, correct vacuum and autoclave tightness. The minimum exposure requirements for a specific shift are: 134°C (+1.5K / -00.0K) dry saturated steam, 3.5 minutes.

Application area
Steam sterilizers of all types.

Package contains PCD device + 100 tests.

Symbol
101.201.0100
Producer code
88-9999001231500
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
Write your opinion
Your opinion:
5/5
Add your own product photo:
IdoSell Trusted Reviews
4.88 / 5.00 16 reviews
IdoSell Trusted Reviews
2025-01-21
Parfait
2025-01-20
TRES BIEN ET CONFORME A LA DEMANDE
pixelpixel